Document Title:APEX-6.5K & APEX 10K INVERTER SPECIFICATIONS
Brand:BigBattery
Model:APEX-6.5K / APEX-10K
Section:Inverter output
Rated Output Power:APEX-6.5K: 6,500W; APEX-10K: 10,000W
Max. Output Power:APEX-6.5K: 13,000VA; APEX-10K: 20,000VA
Rated Output Voltage:120/240 Vac (single-phase / split-phase)
Load capacity of motors:APEX-6.5K: 4 HP; APEX-10K: 6 HP
Rated Frequency:50/60Hz
Output Wave:Pure sine wave
Switching Time:10ms (typical value)
Section:Battery
Battery Type:Lithium-ion battery / lead-acid battery / user-defined battery
Rated Battery Voltage:48V
Voltage Range:40–60Vdc
Max. Solar Charging Current:APEX-6.5K: 140A; APEX-10K: 200A
Max. Grid / Generator Charging Current:APEX-6.5K: 80A; APEX-10K: 120A
Max. Hybrid Charge Current:APEX-6.5K: 140A; APEX-10K: 200A
Section:Solar input
No. of MPPT:1 + 1
Max. Input Power:APEX-6.5K: 5,000W + 5,000W; APEX-10K: 5,000W + 5,500W
Max. Input Current:APEX-6.5K: 18A + 18A; APEX-10K: 22A + 22A
Max. Open Circuit Voltage:550Vdc + 550Vdc
MPPT Voltage Range:125–450Vdc
Section:Grid / Generator input
Input Voltage Range:65–140Vac
Input Frequency Range:50/60Hz
Bypass Overload Current:APEX-6.5K: 40A; APEX-10K: 63A
AC Inputs:APEX-6.5K: 2 inputs (Grid & Generator); APEX-10K: 1 input (Grid or Generator)
Section:Efficiency
Max. Efficiency:99.9%
MPPT Tracking Efficiency:APEX-6.5K: 93%; APEX-10K: 92%
Parallel Capacity:Up to 6 units (3 or more units in parallel can form a three-phase output)
Section:General data
Dimension:APEX-6.5K: 25.51 × 16.14 × 5.51 inches; APEX-10K: 28.46 × 17.64 × 5.91 inches
Weight:APEX-6.5K: 48 lbs; APEX-10K: 62 lbs
Protection Degree:IP20 (indoor only)
Temperature:14–131°F, derate above 113°F
External Module (Optional):Wi-Fi / GPRS
Certificate:UL1741 / RoHS / EN61000-6-1 / EC61000-6-3 / FCC Part15 Class B / IEC62109-1 / IEC62109-2
Noise:<60dB
Cooling Method:Intelligent fan
Warranty:5 years
Communication:RS485 / CAN / USB / Dry contact
Integrated Circuit Breaker:Utility / Load / Battery / PV
Section:Overload protection
Overload protection behavior:After overload protection is enabled, the inverter output will be restored after 3 minutes, and after 5 times of overload, the output will be off until the inverter is restarted. (102% < APEX-10K load < 110%): an error will be reported and the output will be turned off after 5 minutes. (110% < load < 125%): an error will be reported and the output will be turned off after 10 seconds. Load > 125%: an error will be reported and the output will be turned off after 5 seconds.
Protection features:Has PV input current limiting protection, PV input over-voltage protection, PV night reverse current protection, AC input over-voltage protection, AC input under-voltage protection, battery over-voltage protection, battery under-voltage protection, battery over-current protection, AC output short-circuit protection, heat sink over-temperature protection, inverter over-load protection.
SKU#:K0191, K0192, K0193, K0194, K0195
SKU#:K0191, K0192, K0193, K0194, K0195
Warranty
At BigBattery, we stand behind the quality and reliability of our products. Our warranty coverage is designed to give you confidence and peace of mind with every purchase.
-
Battery: Covered by a 12-Year Limited Warranty
-
Inverter: Covered by a 5-Year Limited Warranty
For full details on coverage, terms, and conditions, please visit our Policy Page.